EEPower

Latest Equipment Technical Articles

Categories

Advanced Partial Discharge Testing for Modern Power Modules

Advanced Partial Discharge Testing for Modern Power Modules

Modern power modules need PD testing that goes beyond traditional standards. This article looks at advanced diagnostic methods that help improve…


Sensor Placement Errors in High-Voltage Systems That Distort Measurements

Sensor Placement Errors in High-Voltage Systems That Distort Measurements

Improper sensor placement in high-voltage systems can lead to distorted measurements. This article explains how ground shifts, dv/dt, and layout…


Why Oscilloscope Bandwidth Specs Are Often Misleading for HV Measurement

Why Oscilloscope Bandwidth Specs Are Often Misleading for HV Measurement

Oscilloscope bandwidth can quietly change high-voltage transients and hide the real dv/dt stress, not just probe capacitance or ground inductance.


Probe Capacitance, Ground Inductance Effects in HV Measurements

Probe Capacitance, Ground Inductance Effects in HV Measurements

High-voltage probing errors scale with voltage and dV/dt, as probe capacitance and ground inductance inject energy, distort waveforms, and stress…


Substation Commissioning and Testing—Part 3: Field Testing

Substation Commissioning and Testing—Part 3: Field Testing

Substation field testing ensures long-term reliability. It verifies instrument transformers , circuit breakers, and protection relays against…


Practical Limitations of IEC Partial Discharge Standards in Power Modules

Practical Limitations of IEC Partial Discharge Standards in Power Modules

IEC partial standards miss dv/dt, thermal, and micro-PD effects in power modules, limiting their value for inverter-driven reliability prediction.


Substation Commissioning and Testing—Part 1: Scope and Workflow

Substation Commissioning and Testing—Part 1: Scope and Workflow

Learn how substation commissioning verifies design intent and system integration through FAT, SAT, cold (pre-energization), and hot…


Five Techniques for Fast, Accurate Power Integrity Measurements

Five Techniques for Fast, Accurate Power Integrity Measurements

Learn five techniques for fast, accurate power rail integrity measurements—reduce noise, add…


Double Pulse Testing eGuide

Double Pulse Testing eGuide

This step-by-step guide describes the basic concept of double pulse testing (DPT) and the…


High-Voltage Testing and Insulation Coordination—Part 1

High-Voltage Testing and Insulation Coordination—Part 1

In this article, we explore high-voltage insulation coordination, focusing on the nature of overvoltages, standardized impulse and withstand…


NEC 2023 Basics: Equipment Grounding Conductor Continuity and Connections

NEC 2023 Basics: Equipment Grounding Conductor Continuity and Connections

Learn about equipment grounding conductor continuity and connections.


Determining Series RLC Circuit Resonance Frequency

Determining Series RLC Circuit Resonance Frequency

Learn how to determine the resonance frequency, the component voltages, and current levels at various frequencies in a series RLC circuit.


How Buck Regulators with Integrated Capacitors Help Lower EMI and Save Board Space

How Buck Regulators with Integrated Capacitors Help Lower EMI and Save Board Space

It’s a challenge to create highly efficient and compact designs while also adhering to strict electromagnetic interference (EMI) requirements…


Designing Electronics to Pass the EMC Test Part 2

Designing Electronics to Pass the EMC Test Part 2

Part 1 discussed the conductive emission loop during a typical CE test. Part 2 will examine how to use this information to reduce the emission at…


Power Module Dynamic Test Solution Suitable Also for WBG Devices

Power Module Dynamic Test Solution Suitable Also for WBG Devices

Evaluation of power modules is important for power electronics engineers, as well as power module manufacturers, to design efficient, small form…


Achieving Fast Load-Transient Response and Low EMI with the AECM DC/DC Control Topology

Achieving Fast Load-Transient Response and Low EMI with the AECM DC/DC Control Topology

No single control topology is a good fit for all applications. Designers requiring low electromagnetic interference (EMI) and fast load-transient…


Optimized Sigma-Delta Modulated Current Measurement for Motor Control – Part 1

Optimized Sigma-Delta Modulated Current Measurement for Motor Control – Part 1

This article is Part 1 in a series of two. It discusses demodulation of sigma-delta coded data using sinc filters in a motor control application.…


Transformer Inspection and Testing

Transformer Inspection and Testing

Installing a transformer is more than just connecting the wires, according to the wiring diagram. The first part of the installation process…


Automotive EMC-Compliant Reverse-Battery Protection with Ideal-Diode Controllers

Automotive EMC-Compliant Reverse-Battery Protection with Ideal-Diode Controllers

Given the emergence of new trends in automotive electronics such as autonomous driving and car infotainment systems, system designers are facing…


Speeding up the Design of EMI Filters for Switch-Mode Power Supplies

Speeding up the Design of EMI Filters for Switch-Mode Power Supplies

Switch-mode power supplies are used throughout modern electronics systems mainly because of their high efficiency power conversion. One side effect…