Smart Substations and Digitalization—Part 4: Data Analytics and ML

Smart Substations and Digitalization—Part 4: Data Analytics and ML

Learn how smart substations can leverage IEC 61850 and CIM for data flow. Advanced analytics and machine learning (ML) can turn high-res data into…


Smart Substations and Digitalization—Part 3: Comms and Data Integration

Smart Substations and Digitalization—Part 3: Comms and Data Integration

This article focuses on practical implementation details for communications and data integration in smart substations and reviews predictive…


Multiphysics Simulation and Simulation Apps in Power Electronics

Multiphysics Simulation and Simulation Apps in Power Electronics

Learn how multiphysics-based digital twins are increasingly used to capture interactions in electrification applications, enabling more accurate…


Smart Substations and Digitalization—Part 2: IoT Devices and Sensors

Smart Substations and Digitalization—Part 2: IoT Devices and Sensors

Learn how smart substations use synchronized IoT devices compliant with key standards for high-fidelity data, enabling real-time protection and…


Substation Design and Layout Planning—Part 3: Noise and Oil Control Issues

Substation Design and Layout Planning—Part 3: Noise and Oil Control Issues

In the final part of this series, we examine substation design practices for managing two critical issues: oil containment and noise control.


Switching and Converter Substations

Switching and Converter Substations

This article explores the various functions of switching and converter substations, including network reconfiguration, fault isolation, and AC/DC…


Substation Design and Layout Planning—Part 1: Early Stage Decisions

Substation Design and Layout Planning—Part 1: Early Stage Decisions

In this new article series, we look at substation design and layout planning, starting here with early stage choices and physical layout.


Substation Components—Part 8: Grounding/Earthing Systems

Substation Components—Part 8: Grounding/Earthing Systems

As we wrap up this series, this article outlines the purpose of substation grounding, the IEE Std 80 design, and best-practice field testing.


Thermal Co-Design, Cooling Architecture Optimization, and Reliability Validation

Thermal Co-Design, Cooling Architecture Optimization, and Reliability Validation

Explore electro-thermal cooling design and reliability validation for high-voltage SiC and IGBT power modules.


Substation Components—Part 6: Station Batteries and DC Supply

Substation Components—Part 6: Station Batteries and DC Supply

In substations, the DC system is critical for protection, control, and SCADA during AC loss. Learn about the relevant IEEE standards, choosing the…


Substation Components—Part 5: Busbar Configurations

Substation Components—Part 5: Busbar Configurations

Here, we provide an overview of common substation busbar configurations—Single Bus, Main and Transfer, Double Breaker/Double Bus, Ring Bus/Ring…


Substation Components—Part 4: Isolators

Substation Components—Part 4: Isolators

This article explains the role of substation isolators, covering their purpose in visible isolation and safe operating sequences with breakers and…


Substation Components—Part 3:  Circuit Breakers

Substation Components—Part 3:  Circuit Breakers

This article explores the crucial role of circuit breakers in substations, covering their fundamental functions, interruption processes, and the…


Building Coupled Thermal-Electrical Models for High Voltage Power Modules

Building Coupled Thermal-Electrical Models for High Voltage Power Modules

Learn how to model and manage heat in 4-6.5 kV IGBT and SiC modules using coupled electro-thermal simulations for accurate cooling and reliable…


Orchestrating the Grid: Collaborative Information Server for Smarter, Safer Power.

Orchestrating the Grid: Collaborative Information Server for Smarter, Safer Power.

Yokogawa is a leading provider of Industrial Automation and Test and Measurement solutions.…


Understanding the Role of Substations Along the Transmission Path

Understanding the Role of Substations Along the Transmission Path

This article examines the functions of four different types of substations within the electrical grid: step-up, step-down, transmission, and…


Too Many Cooks in the Circuit: The New Power Grid Risk

Too Many Cooks in the Circuit: The New Power Grid Risk

Creating resilience frameworks for smart grid operations and industrial OT cybersecurity.


High-Voltage Testing and Insulation Coordination—Part 4

High-Voltage Testing and Insulation Coordination—Part 4

In this article, learn methods for mitigating lightning- and switching-induced overvoltages in high-voltage networks through surge arresters,…


High-Voltage Testing and Insulation Coordination—Part 2

High-Voltage Testing and Insulation Coordination—Part 2

Here, in Part 2, we examine insulation coordination and Basic Insulation Level (BIL) in high-voltage systems for reliability against transient…


High-Voltage Testing and Insulation Coordination—Part 1

High-Voltage Testing and Insulation Coordination—Part 1

In this article, we explore high-voltage insulation coordination, focusing on the nature of overvoltages, standardized impulse and withstand…