EEPower

Latest Transmission & Distribution Technical Articles

Categories

Inverter Efficiency: Navigating Measurement Challenges in SiC- and GaN-Driven Systems

Inverter Efficiency: Navigating Measurement Challenges in SiC- and GaN-Driven Systems

If your power inverter measurements show an efficiency of more than 100%, or the measured values sound too good to be true, it could mean you found…


Solving Power System Design Challenges With Point of Load DC/DC Converters

Solving Power System Design Challenges With Point of Load DC/DC Converters

In the quest for improved power supply efficiency, size, speed, and cost, the power supply architecture has evolved.


Medical Converters for Healthy Batteries

Medical Converters for Healthy Batteries

Rechargeable batteries have been used for decades to store electrical energy. Maintenance-free AGM or EFP batteries not only make usage easier and…


Examining the Causes of Transformer Insulation Failure

Examining the Causes of Transformer Insulation Failure

Learn the reasons behind insulation-related transformer failures.


Timeless Tech Wisdom: Foundational Concepts to Advanced Calculations

Timeless Tech Wisdom: Foundational Concepts to Advanced Calculations

Whether it’s FET foundations or calculating transformer turns ratios, these are the EEPower technical articles engineers read time and again.


Current Transformers: Operation, Types, and Polarity Considerations

Current Transformers: Operation, Types, and Polarity Considerations

Learn about current transformers and their essential role in transforming large currents into smaller ones, including winding ratios, types, and…


Winding Connections and Applications of Buck-Boost Transformers

Winding Connections and Applications of Buck-Boost Transformers

This article will teach you about buck-boost transformers, winding connections, and their applications. The primary focus is on boosting (raising)…


Sizing Transformers for Single- and Three-Phase Loads

Sizing Transformers for Single- and Three-Phase Loads

This article spotlights the principles of sizing wye and delta-connected transformers to efficiently handle single- and three-phase loads.


Using Open Deltas Strategically To Increase Transformer Capacity

Using Open Deltas Strategically To Increase Transformer Capacity

Open delta transformers allow delta-connected transformers to supply three-phase loads with two-phase windings while maintaining phase voltages.…


Pros and Cons: Three-Phase Transformer Connections

Pros and Cons: Three-Phase Transformer Connections

This article examines three-phase transformer connections and their advantages and disadvantages, which are crucial for effectively matching…


Making Sense of the Fundamentals and Configurations of 3-Phase Transformers

Making Sense of the Fundamentals and Configurations of 3-Phase Transformers

This article teaches three-phase transformers' fundamental principles and configurations, including their construction with three primary and…


NEC Basics: Impedance-Grounded Systems and Equipment Grounding Above 1 kV

NEC Basics: Impedance-Grounded Systems and Equipment Grounding Above 1 kV

Learn about limiting the available ground-fault current and how to ground equipment above 1 kV.


Using Probability Models to Understand Electrical System Reliability Engineering

Using Probability Models to Understand Electrical System Reliability Engineering

Reliability engineering in electrical systems is essential to ensuring system efficiency. This article explores how probability models are used in…


NEC Basics: Solidly Grounded, Service-Supplied AC Systems Above 1 kV

NEC Basics: Solidly Grounded, Service-Supplied AC Systems Above 1 kV

Learn about single-point and multi-grounded neutrals and service-supplied AC systems above 1 kV.


Exploring Transformers With Dual-Voltage Ratings

Exploring Transformers With Dual-Voltage Ratings

This article explains transformers with dual-voltage ratings and explores their configurations and how the windings can be connected in series or…


Using WBG Switches to Reduce Motor Drive System Losses

Using WBG Switches to Reduce Motor Drive System Losses

An experimental approach to investigate the impact of higher switching frequencies on the inverter and motor efficiency using SiC and GaN


Understanding Transformer Voltage Adjustment Taps

Understanding Transformer Voltage Adjustment Taps

This article explains transformer voltage adjustment taps and their crucial role in maintaining secondary voltage despite fluctuations in the supply.


NEC Basics: Grounding and Bonding DC Systems Supplying Premises

NEC Basics: Grounding and Bonding DC Systems Supplying Premises

Learn whether or not you should connect a direct current power supply to the ground.


Identifying Transformer Leads

Identifying Transformer Leads

This article will help you identify transformer leads by explaining how to determine H or X leads and perform polarity tests to establish lead…


Characterizing Parasitic Components in Power Converters

Characterizing Parasitic Components in Power Converters

This article introduces and explains parasitics in passive components like capacitors, inductors,…