EEPower

The Growing Importance of Arc Fault Detection in Modern PV Systems

Ivtech’s THPA current sensor features a dual-output architecture combining precise current measurement with high-frequency DC arc fault detection for solar and storage safety.


Technical Article 4 minutes ago by Michael Sleven, Ivtech

Article co-authored by Ivtech’s Stéphan Trombert and Tiziano Rossato.

This article is published by EEPower as part of an exclusive digital content partnership with Bodo’s Power Systems.

 

As photovoltaic (PV) systems increase in power and voltage, reliable detection of DC arc faults is becoming increasingly important for system safety and reliability. Early detection of hazardous arc events can help limit thermal damage and reduce the risk of fire.

Standards including IEC 63027 and UL 1699B have established requirements for arc-fault detection and protection, increasing the importance of reliable high-frequency signal acquisition. IVTECH’s THPA current sensor uses a dual-output architecture that combines precision current measurement with a dedicated high-frequency signal channel for arc-fault detection.

 

Image used courtesy of Freepik

 

Necessity of Arc Fault Detection in PV Systems

Understanding the causes and characteristics of arc faults is important when designing effective protection systems.

  • Parallel arcs: Can result from insulation breakdown or conductive paths between DC+ and DC-, or between a conductor and ground.
  • Series arcs: Typically occur at connectors, junction boxes, combiner boxes, switches, and inverter terminals.
  • Root causes: Aging, corrosion, loose connections, mechanical damage, installation defects, and inadequate maintenance.
  • Degraded connections: Increased contact resistance generates heat, accelerates degradation, and can evolve into sustained arc faults.
  • Occurrence: Series arcs are generally considered an important arc-fault mode in PV systems, while parallel-arc events can also occur under insulation-failure conditions.
  • Safety impact: Rapid detection can help limit the duration of an arc event and reduce the risk of thermal damage and fire.

 

Figure 1. Different arc-fault failures [1]. Image used courtesy of Bodo’s Power Systems [PDF]

 

THPA Sensor Integration for Arc-Fault Detection

Integrated into the DC bus, the THPA continuously measures current while its dedicated high-frequency channel captures signal components associated with arc events. The resulting signals can be supplied to a downstream arc-fault detection and protection system.

Figure 2 illustrates the THPA integration in PV and BESS DC bus architectures

 

Figure 2. AFDD integration with THPA. Image used courtesy of Bodo’s Power Systems [PDF]

 

Arc Fault Signature and Detection with THPA

Under normal operating conditions, the PV current waveform generally contains limited high-frequency content. During an arc event, rapid transients and broadband high-frequency components can appear, producing signal characteristics that can be distinguished in both the time and frequency domains.

 

Figure 3. Voltage and current signals in a PV system in the time domain, before and during an arc [1]. Image used courtesy of Bodo’s Power Systems [PDF]

 

To capture these different signal components efficiently, the THPA provides two dedicated outputs: a precision current measurement output and a high-frequency detection output with a high signal-to-noise ratio. This architecture allows the arc signature to be extracted and analyzed without compromising current measurement accuracy, providing a signal suitable for conventional signal processing and AI-based arc-fault classification methods.

 

How the THPA Dual-Output Architecture Works

 

Image used courtesy of Bodo’s Power Systems [PDF]

 

1. Primary current generates a magnetic field

The current flowing through the conductor creates a magnetic flux within the THPA magnetic core (M).

2. Hall ASIC measures the DC/low frequency current component

A Hall ASIC positioned in the air gap accurately measures the magnetic field and provides a precise current signal for system control, monitoring, and protection functions.

3. Dedicated pickup coil captures arc-fault signatures

A separate pickup coil independently detects rapid magnetic field variations generated by switching events and DC arc faults, extending the sensor response far beyond the bandwidth required for conventional current measurement.

The integrated pickup coil shares the existing magnetic structure, providing a high-frequency signal without requiring a separate magnetic core.

4. Passive filtering optimizes the HF signal

The high-frequency signal is conditioned through a dedicated passive filter, extracting the frequency components most relevant for arc-fault detection while maximizing signal-to-noise ratio.

5. Independent measurement and detection outputs

Output 1 – Precision Current Measurement

  • DC to low-/medium-frequency response
  • Accurate current monitoring, control, and protection

Output 2 – Arc-Fault Detection

  • Dedicated high-frequency output
  • High-bandwidth, very high-SNR signal optimized for arc-signature analysis
  • Compatible with conventional signal-processing and AI-based detection algorithms

Compared with a conventional current measurement output, the dedicated arc channel provides significantly higher sensitivity to high-frequency arc signatures, improving detection robustness while maintaining accurate current measurement on the DC channel.

 

Arc Fault Detection Methods

Modern arc-fault detection systems analyze the high-frequency signatures generated by electrical arcs to distinguish genuine faults from normal operating conditions and other electrical disturbances. As shown in Figure 4, the quality of the detection strongly depends on the sensor’s ability to capture these signatures with sufficient bandwidth and signal integrity.

 

Conventional Signal-Based Detection

Conventional arc-fault detection relies on analyzing the time- and frequency-domain characteristics of the current signal. Arc events generate rapid transients, irregular fluctuations, and broadband high-frequency noise that can be identified through filtering and spectral analysis techniques.

The THPA supports this approach through a dedicated high-frequency output optimized for arc-fault detection. Its high bandwidth and excellent signal-to-noise ratio enable reliable extraction of arc signatures, while a separate DC output simultaneously provides accurate current measurement for system control and monitoring.

 

AI-Based Detection

AI-based arc-fault detection can use machine-learning algorithms to analyze multiple features extracted from current and high-frequency signals. Training with representative datasets containing both normal and fault conditions can improve discrimination between arc events and other electrical disturbances. The effectiveness of such methods depends on the quality, diversity, and labeling of the training data.

The performance of such systems depends heavily on the quality of the input data. Thanks to its dedicated arc-detection output, the THPA provides a clean, high-bandwidth signal that preserves the relevant fault information, creating a foundation for advanced AIbased detection methods as well as conventional signal-processing techniques.

 

Table 1. Portfolio THPA, further variants on customer demand.
THPA Variant Nominal Current (Ipn) Max. Current (Ipm) DC/Low frequency Output Bandwidth (-3dB) Arc Output Bandwidth (-3dB) DC Sensitivity Arc Sensitivity (Arc Output) / (DC/Low frequency) Gain Ratio
THPA-30 AFD 30 A 60 A DC-160 kHz 5-400 kHz 33.3 mV/A 230 mV/A x 6.9
THPA-32-AFD 32 A 32 A DC-160 kHz 20-700 kHz 62.5 mV/A 780 mV/A x 12.5
THPA-25 25 A 25 A DC-160 kHz Not available 80.0 mV/A Not available N/A

 

Figure 4. Arc fault detection approaches [2]. Image used courtesy of Bodo’s Power Systems [PDF]

 

Portfolio THPA

THPA sensors combine a precision DC measurement output with a dedicated high-frequency arc-fault output. The arc channel provides enhanced sensitivity and bandwidth, enabling reliable detection of arc signatures while preserving measurement accuracy on the DC channel.

THPA is also available without Arc Output (THPA-25).

 

Summary

Undetected series and parallel arc faults can present significant safety and reliability risks in PV and BESS installations. Effective protection therefore depends on the ability to capture the high-frequency signatures associated with arc events while maintaining practical integration and low system complexity.

By combining a low-frequency Hall-effect measurement with a broadband HF pickup coil within a single magnetic structure, IVTECH’s THPA current sensor provides a dedicated signal path for arc-fault analysis. The resulting high-SNR output is optimized for spectral analysis and AI-based classification, enabling the detection system to extract the characteristic signatures of arc events.

This integrated dual-output architecture provides power-electronics designers with a compact sensing solution for implementing advanced arc-fault protection in PV and battery energy storage system (BESS) applications, without requiring a separate magnetic sensing element for the high-frequency detection path.

 

References

[1] Fronius: Arc Fault Protection Systems

 

This article originally appeared in Bodo’s Power Systems [PDF] magazine and is co-authored by Michael Sleven, Senior Director, Sales Europe, Stéphan Trombert, CTO, and Tiziano Rossato, Sales Manager South Europe; all IVTECH Europe GmbH