EEPower

Measuring High-Side Gate Voltage: Why Bandwidth Alone Is Not Enough

Measuring high-side gate voltage in fast-switching SiC and GaN stages is not just a bandwidth issue. As common-mode transients and dV/dt increase, probe architecture, CMRR, and connection method determine whether the waveform is measured accurately.


Technical Article 2 minutes ago by Marcus Sonst

This article is published by EEPower as part of an exclusive digital content partnership with Bodo’s Power Systems.

Power electronic solutions for data centers and electric vehicles place higher demands on power converters and inverters. Wide-bandgap (WBG) semiconductors like SiC and GaN are central to meeting those demands. They switch faster, reduce losses, and enable denser designs. Those same advantages, however, expose the limits of conventional measurement practice. Capturing gate edges and the Miller plateau on the high side of a half-bridge becomes especially difficult when state-of-the-art probes are used outside the conditions for which they were designed. High-side gate voltage must therefore be measured with care and with a clear understanding of what the setup can achieve.

 

Why High-Side Gate Measurement Is Challenging

High-side gate measurement is demanding for several related reasons. First, a large common-mode voltage such as 600 V from the DC bus appears inherently at the switch node (VDS), as illustrated in Figure 1. The high-side gate signal itself is in the 5 V to 15 V range, yet it rides on that much larger common-mode voltage. The probe must therefore resolve a small differential signal in the presence of a large, rapidly changing reference.

 

Figure 1. Common-mode noise in half-bridge converter/inverter. Image used courtesy of Bodo’s Power Systems [PDF]

 

Second, common-mode rejection must hold not only in the static on and off states of the switches, but also during transitions. Those transitions are characterized by the slew rate dV/dt. High slew rates contain substantial high-frequency content, and suppressing common-mode voltage under those conditions is far harder than rejecting a steady high voltage. In practice, conventional high-voltage differential probes do not guarantee a trustworthy high-side gate waveform when slew rates increase above 10 V/ns.

 

Traditional Measurement Solutions

A high-voltage differential probe is often the first tool engineers reach for when measuring high-side gate-source voltage (Vgs). Its limits appear exactly when the switch-node voltage rises quickly. The core issue is not simply “insufficient bandwidth.” The larger problem is that the probe remains earth-referenced, and its common-mode rejection ratio (CMRR) falls with frequency, precisely where WBG switching puts the most stress on the measurement.

A conventional high-voltage differential probe follows a symmetrical concept (Figure 2). Two matched resistive dividers feed a differential amplifier. That architecture is still tied to earth ground, typically the oscilloscope ground. Both the desired differential signal and the unwanted common-mode voltage are attenuated by the same factor. When the differential signal is small, and the common-mode voltage is large, high attenuation is required. The residual differential signal then sits closer to the noise floor, and measurement accuracy suffers.

 

Figure 2. Block diagram of a standard high-voltage differential probe. Image used courtesy of Bodo’s Power Systems [PDF]

 

A common-mode path still exists through probe parasitics, so common-mode current can flow. Effective rejection therefore depends on very close matching of the two divider paths up to high frequency. This is difficult to maintain in real probe hardware.

Most conventional high-voltage differential probes connect to the device under test (DUT) with banana leads and pincer clips. That arrangement is convenient and safe for bench work, but it limits bandwidth, CMRR, and measurement repeatability. Long leads and large loop areas also invite coupling of high electromagnetic fields into the measurement path, which further corrupts the waveform.

When common-mode rejection is inadequate during fast switch node edges, the displayed high-side Vgs often shows artifacts that are easy to misread as device behavior. The waveform may exhibit extra ringing or spikes on high-side Vgs that are not real gate signals. The Miller plateau region may also appear distorted, leading to incorrect timing conclusions. In other cases, the waveform may look over-filtered, hiding true edge and plateau detail. In other words, the probe can make the gate look faster, noisier, or softer than it really is, depending on how the common-mode error and the probe’s bandwidth interact.

A conventional high-voltage differential probe is still useful within its limits. This is especially true when the frequency content of the common-mode voltage edge remains below roughly 10 MHz, where CMRR in the range of about 40 dB to 50 dB is still achievable. It is also more suitable when the ratio of differential voltage to common-mode voltage is more favorable, for example in drain-source measurements, than in high-side Vgs. In addition, bandwidth expectations must be kept realistic. Datasheet values around 250 MHz are common and realistic. Probes rated up to 500 MHz exist, but tip-lead length, loop area, and fixture resonances usually dominate, so the usable fidelity is often lower than the headline bandwidth suggests.

 

Optical Isolated Measurement Solutions

The most effective way to overcome the CMRR limits of conventional high-voltage differential probes is to break the electrical earth connection between the probe front end and the oscilloscope receiver. Bandwidth, dV/dt immunity, and safety then improve together, because the measurement no longer relies on two tightly matched, earth-referenced divider paths to reject a large, fast common-mode voltage.

In an optically isolated probe like the R&S RT-ZISO from Rohde & Schwarz, the probe head sits close to the DUT potential. A coaxial probe tip connects that head to the measurement point. The front end converts the measured electrical signal into an optical signal and transmits it to a receiver box. That optical link removes the common-mode ground loop that exists in an earth-referenced differential probe and therefore reduces disturbance during fast switch-node transitions (Figure 3).

 

Figure 3. Block diagram of optically isolated probe for WBG applications. Image used courtesy of Bodo’s Power Systems [PDF]

 

Fully optical isolation between the DUT and the oscilloscope is the main reason these systems can reach very high CMRR because parasitic capacitance to earth is kept extremely low. Therefore, only a small amount of common-mode current has a conductive path back to the instrument (earth).

Unlike a conventional high-voltage differential probe, the isolated architecture is essentially single-ended. That eliminates the need for two closely matched high-voltage attenuators and simplifies the amplifier circuit. The remaining critical element is the reference impedance of the coaxial return/shield. Common-mode current can still flow in the shield. This current produces a voltage drop along the return if the return impedance is not kept very low. The drop appears as an error on the measured signal and degrades fidelity. A well-defined coaxial path is therefore an essential part of the electrical design.

Probe tips based on a coaxial structure, with different attenuation factors, improve noise immunity and provide several input voltage ranges. Connecting the tip to the DUT with an MMCX coaxial connector is the preferred approach. Compared with banana leads and pincer clips, electromagnetic coupling into the measurement path is reduced; the tip geometry is defined and belongs to the probe, so bandwidth is more repeatable, and high CMRR remains possible at high frequency.

With a properly designed printed circuit board test point, such a system can achieve CMRR in the order of 80 dB at 1 GHz. In practice, 80 dB at 500 MHz is achievable with a 10:1 tip, and the probe can operate at frequencies up to 1 GHz. Those figures are only realized if the connector and layout are treated as part of the measurement chain.

Optical isolation brings several advantages that matter directly for high-side Vgs. It enables higher usable bandwidth together with higher CMRR, provides galvanic isolation between the DUT and the oscilloscope, and uses defined coaxial tips that improve both noise immunity and repeatability.

Rohde & Schwarz has made a notable implementation detail in its R&S RT-ZISO isolated probing system (Figure 4): a dedicated frontend with multiple input ranges. That is especially important when very small voltages must be measured across a current shunt in the presence of large common-mode swing. A more sensitive range improves noise performance without giving up isolation. Isolated probing does not make bandwidth irrelevant. It changes the problem. Once the earth loop is interrupted and the tip is coaxial and defined, bandwidth and CMRR can be high at the same time.

 

Case Study: Comparing Probe Performance

A synchronous DC/DC step-down converter (40 V to 5 V, output current 5 A) using ultrafast GaN switches was selected to compare different probing solutions for measuring the high-side gate voltage.

 

Figure 4. R&S RT-ZISO isolated probing system with MXO 5 oscilloscope. Image used courtesy of Bodo’s Power Systems [PDF]

 

This DUT provides an MMCX connector that was integrated into the PCB to achieve the highest measurement fidelity. According to the design, the GaN switches may reach tr = 1,4 ns rise time and thus, a minimum system bandwidth of 285 MHz is required. The bandwidth can be calculated as follows:

fbw = 0.4 / tr.

The measurement setup consisted of an MXO 5 oscilloscope with a bandwidth of 2 GHz, a single-ended passive probe with an MMCX connection and a bandwidth of 700 MHz, and three different differential probes that were compared on the same DUT.

 

Probe Type fbw CMRR @ 200 MHz Attenuation
Optical Isolated Probe 1 GHz > 80 dB 10:1 ( 300 V max )
High Speed Diff. Probe 1 GHz > 20 dB 100:1 ( 60 V max )
High Voltage Diff. Probe 200 MHz > 35 - 40 dB 25:1 ( 75 V max )

 

The two conventional differential probes were attached to the DUT using an MMCX-To-Pin header adapter. The reason was to compare the probes only and to reduce the impact of the connection method. However, the adapter will have an impact on CMRR, but the impact is less than 5 dB.

The switch node waveform (C1-Uds) was measured with a single-ended passive probe such as the R&S RT-ZPMMCX, which provides sufficient bandwidth and an MMCX connection. The result clearly shows a rise time of approximately tr = 1.98 ns. The waveforms of all high-side gate voltages were acquired sequentially, and thus two of the results are displayed in reference channels (R3-Ugs_B and R4-Ugs_C). The measurement with the optical probe was captured on channel C2-Ugs_A.

Figure 5 compares the gate-source voltage measurements. The R&S RT-ZISO optically isolated differential probe shows the best measurement result in terms of signal fidelity. It shows a clean rising gate voltage, including the visible Miller plateau. The waveform includes ringing of 400 mV peak-to-peak. This implies that with CMRR > 80 dB, you get small details up to 1 GHz, but you also will not see an artifact due to CMRR. The maximum CM-induced peak would be about 4 mV (80 dB = 10000:1). The reason it shows larger values is due to real effects such as switch and PCB parasitics.

The high-speed differential probe shows strong ringing at a similar frequency compared to the optical probe result. However, the high magnitudes and overshoots are caused by a small CMRR of about 20 dB. This measurement does not reflect the reality of the DUT. The high-voltage differential probe also shows strong ringing, but at a lower frequency. This low-frequency ringing is caused by insufficient bandwidth (200 MHz) of the probe. It acts like a low-pass filter. Furthermore, it resonates and produces peaks and overshoots. Although CMRR is higher (30 - 40 dB), this measurement does not reflect the reality of the DUT as well.

 

Figure 5. Gate-source voltage measurement comparison. Image used courtesy of Bodo’s Power Systems [PDF]

 

Conclusion

Converter/inverter power electronic solutions based on WBG technology switch fast enough that high-side gate measurement can no longer be treated as a simple bandwidth problem. The desired Vgs is only a few volts, yet it rides on a large switch node common-mode voltage whose dV/dt content is hard to reject. Conventional high-voltage differential probes remain useful when slew rates stay below roughly 10 V/ ns. If engineers are unaware of this limit, typical results are false ringing, a distorted Miller plateau, and over-filtered edges. Optically isolated probes break the earth connection and use a defined coaxial MMCX path, so bandwidth, CMRR, and safety improve together.

For high-side gate measurements on fast SiC and GaN switching stages, waveform fidelity depends not only on bandwidth but also on probe architecture, common-mode rejection, and connection method. If the common-mode transients are large and fast, conventional differential probes can create misleading artifacts. Optically isolated probing with a defined coaxial connection offers a more reliable way to capture the real high-side Vgs waveform.

 

This article originally appeared in Bodo’s Power Systems [PDF] magazine.