New Current Sensors Measure Higher Currents While Staying the Same Size

May 09, 2019 by David Barbagallo

This article highlights LEM three new families of compact open-loop current sensors that measure higher currents than earlier sensors of the same size.

As power electronics systems get smaller LEM is introducing 3 new families of compact open-loop current sensors which measure higher currents than earlier sensors of the same size, or similar currents with smaller size. Excellent performance is obtained using a single custom ASIC to perform all signal processing and analog correction functions.  This article describes the sensors and their key electrical characteristics. It concludes with some application examples.

 

Introduction

The current measurement trend today in for example UPS systems and in power generation from renewable sources continues towards smaller physical size, higher current ranges, faster response times that go with faster switching frequencies, and of course lower cost. The simplicity of open-loop sensors makes them an attractive solution for attaining these objectives.

In this article we present three new families of sensors which allow the nominal current to be as high as 800 Amps RMS and detection of an overcurrent up to seven times higher. The miniature HLSR xx/SP10 sensors are an extension of the existing HLSR family with an integrated primary conductor; they are mounted on a PCB and are the best choice if small physical size is important.

The two other families, HOYS and HOYL are busbar mounted with new magnetic circuits optimized for weight and size. The open-loop HLSR and HO sensors introduced by LEM 5 years ago indeed meet the objectives of size, accuracy, speed and cost but the nominal primary current of the smaller HLSR is limited to about 50 Amps by saturation of the ferrite magnetic circuit. (Reference 1).

 

Closed-Loop Sensors

Often closed-loop sensors have been used to meet the accuracy and speed requirements of high current sensors but the secondary coil which cancels the magnetic field from the measured current adds to the device size, current consumption, complexity and cost.

 

Open-Loop System

In high current devices the secondary must be driven from a high supply voltage or complex electronics. A preferred approach is to use an open-loop architecture in which the imperfections inherent in an open-loop system are mastered by using a complex ASIC as the magnetically sensitive element.

This technique was already used in the earlier lower current sensors: any errors of sensitivity or offset, including their drift with temperature, are measured during the ASIC production test and stored in it. The corrections needed are applied continuously when it is used and most electrical parameters approach the level of the previous generation of closed-loop sensors.

 

HLSR xx/SP10 Sensors

Figure 1 shows one of the high current HLSR xx/SP10 sensors. It has the same small physical dimensions and footprint as the existing family members, but the maximum nominal current is extended from 50 to 120 Amps by a new FeSi magnetic circuit. In all cases the maximum current which can be measured is 2.5x the nominal current. The HLSR has an integrated primary and is mounted on a PCB. The four other connections to it are for the secondary side supply, the output voltage VOUT and a reference voltage VREF. VOUT – VREF is proportional to the measured current.

 

Figure 1: an HLSR xx/SP10 sensor
Figure 1: an HLSR xx/SP10 sensor
Figure 2: HOYL (left) and HOYS (right) sensors
Figure 2: HOYL (left) and HOYS (right) sensors

 

HOYS and HOYL Sensors

Figure 2 shows the new HOYS and HOYL sensors which are respectively ‘small’ and ‘large’ devices for mounting on busbars up to 21 x 12 mm and 39 x 12 mm respectively. Together they cover the current range from 100 to 800 Amps – with a maximum measurable current of 2000 Amps.

These sensors have a fifth output pin, OCD, which shows that an overcurrent condition has been detected on the primary current. Their compact size is due to the optimization of the magnetic circuit and package around the busbar and because there are no electronic components inside the sensors except the Hall effect ASIC and two decoupling capacitors.

 

Sensor Performance

The supply for the measuring (secondary) side of the sensors is 3.3 V or 5V and the output is referenced to half that value, generated by the sensor (although other reference voltage values may be forced from an external source). Apart from the variations in size and mounting arrangement the differences in performance between the HLSR and HOY families are mainly due to their magnetic circuits.

In sensor applications switching speeds are rising and therefore response times must be shorter so that unusually high current and short-circuit conditions are detected quickly. In the new sensors the CMOS ASIC contains Hall cells as the magnetically sensitive element and all the signal processing circuits. A high clock speed is used to give a fast response time, less than 3.5 us, while filters minimize the noise at the sensor output by limiting the ASIC signal path bandwidth to that needed to pass the current waveform.

Two of the most important characteristics of high current sensors are linearity and, when the primary is part of the sensor, thermal dissipation. A comprehensive series of simulations and tests has been performed to validate these aspects of the new sensors.

 

HLSR xx/SP10 Magnetic Circuit Capability

The capability of the HLSR xx/SP10 magnetic circuit was validated by building a test sensor with an IPN of 180 Amps, 50% above the highest production value, and measuring its linearity. The result for a current of IPM (+/-450 Amps) is shown in figure 3a. The curve shows the difference between the measured output and an ideal perfectly linear output. With a maximum of 0.5% of IPN it demonstrates that the linearity specification for the series sensors is attained with good margin. (Note that short current pulses were used for this test, 450 Amps is too high for a continuous current in the primary.)

 

HOYS and HOYL Sensors Capabilities

The capabilities of the HOYS and HOYL sensors are shown by their linearity in figures 3b and 3c respectively. In these tests the primary current covered the range +/- IPM, but the linearity error is expressed relative to IPN, a more demanding specification.

 

Figure 3a: example of linearity and magnetic offset of an HLSR xx/SP10 sensor
Figure 3a: example of linearity and magnetic offset of an HLSR xx/SP10 sensor
Figure 3b: example of linearity and magnetic offset of an HOYS sensor
Figure 3b: example of linearity and magnetic offset of an HOYS sensor
Figure 3c: example of linearity and magnetic offset of an HOYL sensor
Figure 3c: example of linearity and magnetic offset of an HOYL sensor
Figure 4: Thermal simulation of the primary of an HLSR xx/SP10 sensor
Figure 4: Thermal simulation of the primary of an HLSR xx/SP10 sensor

 

For the HLSR xx/SP10 sensor, whose primary is part of the device, it is important to know the thermal characteristics when a high current passes through it. Clearly the sensor heating depends on the PCB to which it is soldered as well as the sensor itself.

 

PCB Technology

Today’s PCB technology allows for maximum currents of around 100 Amps: in the example simulated here all of the four layers of the PCB are used; its design and cooling by natural convection maintain the solder joints at 100 °C in an environment at 85 °C. Figure 4 shows the results – only the sensor primary is shown, however for the simulation it is situated as usual in the sensor housing. With a current of 120 Amps DC the hottest part of the primary stabilizes at 113 °C, just lower than the 120 °C maximum allowed.

 

Overcurrent Detection

A particularly useful feature of the HOYx sensor family is overcurrent detection (OCD). The input used for OCD detection is taken before the sensor output amplifier and filters – see the simplified block diagram of figure 5.

This has two advantages:

  • the signal here is of lower amplitude so a current level higher than that which saturates the sensor output can be detected,
  • and the OCD response time is faster than that at the output.

By default the OCD threshold is set at 2.93x IPN but 15 other multiples from 0.68x IPN to 7.06x IPN may be selected at the time of ordering the sensor. The exact multiples available are shown in the datasheets (Reference 2): in the most extreme case an OCD level of 5’648 Amps may be chosen for the 800 Amp version of the HOYL sensor. Note that OCD levels are accurate only to 10 or 20%, depending on the level chosen, but this is more than good enough for the fast warning function that OCD performs.

 

Figure 5: the OCD system
Figure 5: the OCD system
Figure 6: current and sensor waveforms when the OCD is triggered
Figure 6: current and sensor waveforms when the OCD is triggered

 

Figure 6 shows an example of the OCD output: the primary current (yellow) is ramped up above the level which saturates the sensor out-put (red); 2.3 us after the OCD threshold is crossed its output (blue) falls to 0V. The OCD output is an open drain which allows several to be connected to a single warning line. The spread of OCD response times is due to the primary current not being synchronized with the sensor clock.

The new sensors have excellent isolation characteristics. In all of the HLSR and HOY sensors there is full galvanic separation between the primary and secondary circuits. For example, the 1.2/50 μs ‘impulse withstand’ insulation test allows 8 kV with the HLSR sensors and 9.6 kV with the larger HOYL family.

 

Sensor Reliability

Sensor reliability is another important consideration: the construction of open-loop current sensors is extremely simple, with only one active component – the Hall effect ASIC – and very few solder joints (none at all in the case of the HLSR family). The reliability of this sensor type is therefore excellent, with a FIT rate of 3.4, corresponding to a MTTF of 294’170’980 hours.

Table 1 shows a summary of the principal electrical characteristics of the HLSR xx/SP10 and HOY sensors. The complete details are in the product datasheets

 

Parameter HLSR xx/SP10 HOYS / HOYL Comment
Nominal Current, IPN (A) 80 - 120 100 - 800  
Maximum Current, IPM (A) 200 - 300 250 - 2000  
VOUT – VREF (mV 800 800 5V supply; Input current = IPN
Response time (us) 2.5 3.5  
Bandwidth (-3dB) (kHz) 250 180 / 140 Small signal
Noise at the output (mVpp) 8.8 5.8 – 8.6 In 100 kHz bandwidth
OCD available No Yes  
Overall accuracy (% of IPN) +/-1.0 +/-1.0 to +/-1.25 At 25 oC
Overall accuracy (% of IPN) +/-3.8 +/-3.8 to +/-4.0 At 105 oC
Impulse withstand voltage (kV) 8 9.6 1.2/50 us rise/fal
Footprint (cm2) 3.87 11.0 / 17.8
Table 1 - summary of the principal electrical characteristics of the HLSR xx/SP10 and HOY sensors
 

Application Example 1: UPS Get Smaller

Uninterruptible Power Supplies (UPS) are being driven by two technology trends: faster switching devices allow lower value reactive elements to be used; these are physically smaller so the electronics can all be PCB mounted – and of course the current sensors have to follow the same size trend so as not to dominate the PCB surface. At the same time, higher currents can be passed by using many or all of the layers on multi-layer PCBs – some layers may be thick and dedicated to high current capacity.

 

Figure 7: HLSR xx/SP10 sensors in a UPS system
Figure 7: HLSR xx/SP10 sensors in a UPS system

 

The HLSR xx/SP10 sensor is ideally situated at the intersection of small size, high current ranges and PCB mounting. Figure 7 shows a simplified application schematic in which HLSR xx/SP10 may be used in the control loop for the switches used both for AC to DC and DC to AC conversion.

 

Application Example: Large Measuring Range and OCD for Wind Turbines

In this application the large current measuring range and the OCD feature of the HOYx sensors can be useful. The generator driven by a wind turbine may use power from the network it drives for its stator coils. See figure 8: the AC/AC converter output when mixed with AC current from the generator creates the correct 50 Hz waveform for the network which is powered. If the network load draws too much current the power available for the generator may become insufficient, worsening the effect of the excessive load and, if there is no LVRT

 

Figure 8: HOYx sensors in a wind turbine system with LVRT
Figure 8: HOYx sensors in a wind turbine system with LVRT

 

(Low Voltage Ride Through) capability, the failure of one generator may propagate through the network and cause others to fail. Part of the LVRT solution is to detect overcurrent on the network side, where the large HOYx measuring range is advantageous; the OCD feature is useful to decide different corrective actions and to confirm that current spikes have disappeared. The low physical size of the HOYx sensors makes them easy to deploy in these applications.

 

Conclusion

This article has introduced new sensors allowing currents of up to 2000 Amps to be measured using a simple low cost open-loop architecture. In many cases their performance will allow them to be used instead of more complex sensors. Their compact size, low supply voltage and the HOYx OCD feature will give designers new possibilities to implement efficient and economic systems.

 

About the Authors

David Barbagallo works as the Research and Design Program Manager at LEM International SA located in Switzerland. He earned his Bachelor's Degree in Electrical Engineering at the University of Applied Sciences Western Switzerland. He then acquired his Master's Degree in Business Administration, Executive MBA, Entrepreneurship and Business Development at the University of Geneva.

Pierre Turpin was born on December 10, 1958. Pierre Turpin is managing director of the company Lem Tech France which was created in 2017.

Thomas Hargé received his Master of Science in Microelectronics at Higher School of Electronic Physics Chemistry of Lyon. He worked as a Vice President Of Product Management at LEM, which is a focused manufacturer and global market leader in producing high-quality transducers for measuring electrical parameters.

 

Reference

  1. LEM HLSR
  2. LEM HOYL
  3. LEM HOYS

 

This article originally appeared in the Bodo’s Power Systems magazine.